branes with very low levels of extractables are available on some Corning syringe filters Cellulose nitrate (CN) membranes are recommended for filtering solutions where protein binding is not a concern They are recommended for use in general laboratory applications such as buffer filtration Corning's cellulose nitrate membranes are Triton X-100-free and noncytotoxic Nylon membranes 30 mm glass syringe filters with a 0 7 um pore-size were purchased from National Scientific Co (F2500-18) (Quakertown PA) and 25 mm glass syringe filters with a 1 um pore-size were purchased from Pall Life Science (4523T) (East Hills NY) 25 mm glass filter discs with a 0 7 um pore-size were purchased from Millipore (APFF02500) (Billerica MA) and the filter holder was from Sterlitech

Sartorius Filters Filtration Products

At Analytics Shop we stock a wide variety of high-quality filtration products from Sartorius such as glass fiber filters membrane filters syringe filters filter papers gelatine filters quartz fiber filters etc The Midisart and Minisart syringe filters are among Sartorius's best-known brands Use the drop-down menu on the left to select the filter type pore size diameter and

Buy Kinesis KX Glass Fiber Syringe Filters with Prefilter and more from our comprehensive selection of Syringe Filters from Cole-Parmer Germany COVID-19 Update: To support you Cole-Parmer is open for business and shipping product daily

Glass Fiber Filters and Prefilters Membranes for Filtration Syringe and Syringeless Filters Water Testing and Environmental Analysis Tubes Vials Tubes and Vials Centrifuge Tubes Microcentrifuge Tubes PCR Tubes Test Tubes Tube Racks and Storage Autosampler Vials Caps and Closures Cryogenic Storage Vials Sample Vials Scintillation Vials Vial Racks and Storage Custom Assays

Glass Fiber Prefilters For viscose solutions or for turbid liquids Glass microfiber prefilter raises absorption capacity and loading Ideal for use as a prefilter in series with other syringe filters Glass microfiber filter media enclosed in this series is binderless

Glass Fiber syringe filters act as a valuable prefilter to extend membrane life with viscous samples For hard-to-filter samples such as tissue culture media or samples with large particulate loads Glass Fiber Syringe Filter Availability: Pore Sizes: 0 7 m to 3 1 m Diameter: 30 mm Polypropylene housing with Luer-lock inlet and male Luer slip outlet Available in 13 mm and 25 mm

Syringe Filters

Omicron Scientific Syringe filters with prefilter (glass fiber filter) enhance the throughput rate by retention of particle 2 0 micron size at prefiltration stage Omicron Scientific Syringe filters with prefilter (glass fiber filter) are suitable for highly turbid or milky solutions

• AXIVA Syringe filters with prefilter (glass fibre filter) enhance the throughput rate by retention of particle 2 0 micron size at prefiltration stage • AXIVA Syringe filters with prefilter (glass fibre filter) are suitable for highly turbid or milky solutions • They are widely applicable for filtration of

ReliaMAX™ syringe filters are manufactured with a total of three layers: two microfiber glass pre-filters set before a polymeric membrane filter The filter design enables a fast initial flow of viscous samples as well as a high particle holding capacity Our tests show that ReliaMAX™ multi-layer syringe filters perform better than standard filters and can reduce the number of steps

Glass fiber filters without binder Glass fiber filters with binder Quartz fiber filters Membranes Extraction thimbles Cellulose extraction thimbles Glass fiber extraction thimbles Special filter products Weighing aids Phase separation papers Lens paper - Jos paper Ion exchange papers Antibiotic resistency paper Surface protection

Titan3 GMF (Glass MicroFiber) Syringe Filters are often used for dissolution testing They are also well-suited for general filtration applications Contact us for support › Back to top With a robust design that includes a reinforcing outer ring configuration and integral pre-filter Titan3 Syringe Filters are an ideal choice for high solids applications or where maximum confidence is

These Corning syringe filters have acrylic copolymer housings Luer lock inlets and male Luer slip outlets SFCA-PF (surfactant-free cellulose acetate with prefilter) membranes provide the lowest protein binding and have an integral glass fiber prefilter for extra filtering capacity integrity tested sterile and certified nonpyrogenic and noncytotoxic Manufactured in accordance

Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis Filtering liquids the single-use devices force liquids through the filter either when fluids are initially drawn or delivered Circular shaped in diameters that fit common syringe sizes the cartridges remove fragments that would otherwise damage narrow bore equipment Certified for low

Glass Fiber syringe filters feature high dirt-loading capacity along with high throughputs They are commonly used for solvent filtration where it is necessary to avoid binder extractions Other applications include: Pre-filtration of viscous serums and tissue media samples prior to analysis filtration of cell media separations prior to sterilization and clarification of dirt particulate

Syringe Filters

Omicron Scientific Syringe filters with prefilter (glass fiber filter) enhance the throughput rate by retention of particle 2 0 micron size at prefiltration stage Omicron Scientific Syringe filters with prefilter (glass fiber filter) are suitable for highly turbid or milky solutions

Glass Fiber syringe filters feature high dirt-loading capacity along with high throughputs They are commonly used for solvent filtration where it is necessary to avoid binder extractions Other applications include: Pre-filtration of viscous serums and tissue media samples prior to analysis filtration of cell media separations prior to sterilization and clarification of dirt particulate

Microbiological filters from a variety of reputable manufacturers are available through Hach including Pall Millipore Xenomax and Gelman Commonly used in detection and enumeration of coliform organisms 0 45 m 47 mm diameter filters are available in various quantities along with 25 mm sizes and different pore diameters

Syringe filters are routinely used in preparation for analysis of pesticides herbicides fungicides flavors and fragrances For samples with large amounts of particulate and/or large fibrous matter use a glass fiber prefilter Applications: Environmental Pharmaceutical / Biotech Clinical / Toxicology Food and Beverage Syringe filter Specifications Materials of Construction Housing

Glass Fiber Filters and Prefilters Membranes for Filtration Syringe and Syringeless Filters Water Testing and Environmental Analysis Tubes Vials Tubes and Vials Centrifuge Tubes Microcentrifuge Tubes PCR Tubes Test Tubes Tube Racks and Storage Autosampler Vials Caps and Closures Cryogenic Storage Vials Sample Vials Scintillation Vials Vial Racks and Storage Custom Assays

For maximum sample recovery choose Sterlitech's sterile cellulose acetate syringe filters Low-binding and hydrophilic these sterile cellulose acetate syringe filters are available with or without a glass fiber pre-filter and boast both strength and a uniform pore size throughout their cellulose acetate membrane Sterile Cellulose Acetate Syringe Filter Product Characteristics: hydrophilic

High Efficiency Glass Fiber Syringe Filters 25mm Choose Style pack/200 High Efficiency Glass Fiber Syringe Filters 25mm Choose Style pack/200 List: $385 00 $352 60 (You save $32 40) Part Number: ENV-SF012G Lead Time: 5 days Shipping: Free Shipping on most orders* Bulk Pricing: Buy in bulk and save Bulk discount rates Below are the available bulk discount rates for each individual

Syringe filters Acrodisc glass fibre Supplier: Pall Laboratory Acrodisc PALLAP-4529EA 3730 SGD PALLAP-4529 PALLAP-4527 PALL4524 PALL4523 PALL4529 PALLAP-4523 Syringe filters Acrodisc glass fibre Filters Syringe Filters Maximise throughput for hard to filter samples Reduce clogging use alone or in series with final membrane filter to increase flow rate and throughput